covidien kendall scd 700 series user manual

Covidien Kendall SCD 700 Series User Manual: A Comprehensive Guide

This manual serves as a comprehensive resource for understanding and operating the Kendall SCD 700 Series. It covers everything from initial setup to troubleshooting‚ ensuring safe and effective use. Service technicians should familiarize themselves with this material for optimal device maintenance and operation.

The Kendall SCD 700 Series is a clinically proven system designed to prevent venous thromboembolism (VTE) and deep vein thrombosis (DVT) through sequential compression therapy. This all-in-one device offers improved functionality and convenience‚ delivering either leg or foot compression based on the chosen therapy. Its Vascular Refill Detection technology personalizes treatment by detecting each patient’s individual vascular refill time.

The system is versatile‚ offering both bilateral operation and a battery backup that provides up to eight hours of continuous therapy‚ enhancing patient mobility. The Kendall SCD 700 Series controller features user-friendly maintenance‚ covered in detail within this manual. Service technicians will also find valuable information regarding the operating principles and troubleshooting procedures for the device.

This comprehensive guide provides essential information for healthcare professionals and service personnel‚ ensuring they are well-equipped to operate and maintain the Kendall SCD 700 Series effectively. Proper understanding and adherence to the guidelines outlined in this manual are crucial for maximizing the benefits of this compression therapy system.

Indications for Use of the Kendall SCD 700 Series

The Kendall SCD 700 Series compression system is indicated for several key clinical applications. Primarily‚ it is used for the prophylaxis of deep vein thrombosis (DVT) and pulmonary embolism (PE)‚ helping to prevent these potentially life-threatening conditions in at-risk patients. When used with leg sleeves‚ the system provides sequential compression to promote blood flow and reduce the risk of stasis.

Furthermore‚ the Kendall SCD 700 Series can be used with foot cuffs to enhance circulation. This is particularly beneficial for patients with conditions such as acute edema. The foot compression mode is also indicated for DVT prophylaxis in certain patient populations. The system’s versatility allows healthcare providers to tailor the therapy to meet specific patient needs.

In summary‚ the Kendall SCD 700 Series is indicated for DVT and PE prevention‚ circulation enhancement‚ and edema management. Understanding these indications ensures that the device is used appropriately to maximize its therapeutic benefits and improve patient outcomes. Always refer to a healthcare professional to determine the suitability of this therapy.

Contraindications for Use

While the Kendall SCD 700 Series is a valuable tool for VTE prevention‚ it is essential to understand the contraindications for its use. This device should not be used on patients with severe arterial insufficiency‚ as the compression could further compromise blood flow to the affected limb. Patients with known or suspected deep vein thrombosis (DVT) or active thrombophlebitis should also avoid using this system.

Additionally‚ patients with severe congestive heart failure or pulmonary edema should not use the Kendall SCD 700 Series‚ as the increased venous return could exacerbate their condition. The device is also contraindicated for individuals with any condition where increased fluid mobilization is undesirable. Local skin conditions‚ such as dermatitis‚ cellulitis‚ or open wounds‚ are also reasons to avoid using the compression system on the affected area.

Finally‚ patients with significant peripheral neuropathy or any condition that impairs their ability to sense pressure or pain should be carefully evaluated before using the device. Understanding these contraindications is crucial for ensuring patient safety and preventing potential harm. Always consult with a healthcare professional to determine if the Kendall SCD 700 Series is appropriate.

Key Features and Benefits

The Kendall SCD 700 Series boasts several key features designed to enhance functionality and patient care. One notable benefit is its Vascular Refill Detection technology‚ which customizes therapy by adapting to each patient’s individual vascular refill time. This ensures optimal compression and improved effectiveness in preventing VTE.

The system supports both leg and foot compression‚ offering versatility to meet diverse patient needs. Its user-friendly interface simplifies operation and reduces the learning curve for healthcare providers. The integrated battery backup allows for continuous therapy during patient transport or power outages‚ providing up to eight hours of uninterrupted use. The compliance meter monitors therapy delivery time‚ aiding in tracking patient adherence.

Furthermore‚ the Kendall SCD 700 Series is designed for bilateral use‚ allowing simultaneous compression of both legs. The device’s portability and compact design make it easy to move and store. The system’s ability to move more blood and prevent stasis contributes significantly to VTE prevention. These features combine to make the Kendall SCD 700 Series a powerful and convenient tool for promoting patient well-being.

Operating Instructions

To begin operating the Kendall SCD 700 Series‚ first verify that all components are present and undamaged. Connect the tubing to both the controller and the appropriate leg sleeves or foot cuffs‚ ensuring a secure fit. Position the sleeves or cuffs on the patient‚ ensuring a snug but comfortable fit‚ allowing space for two fingers between the sleeve and the leg.

Power on the controller using the power button. The system will initiate a self-test. Select the desired compression mode (leg or foot) and adjust the pressure settings according to the physician’s orders. Monitor the patient closely during the initial compression cycles to ensure proper function and comfort.

Regularly check the tubing for kinks or obstructions that may impede airflow. The system is designed for continuous use‚ but it’s important to periodically assess the patient’s skin for any signs of irritation or discomfort. To stop the therapy‚ press the power button to turn off the controller. Disconnect the tubing and remove the sleeves or cuffs from the patient. Always follow established infection control protocols when handling and cleaning the device and accessories.

Understanding Error Codes and Troubleshooting

The Kendall SCD 700 Series utilizes a system of error codes to alert users to potential issues affecting device performance. These error codes are categorized into User Resettable‚ Manual Reset Required‚ and Service Required errors‚ each demanding a specific course of action. User Resettable errors typically indicate minor issues that can be resolved by the user.

Manual Reset Required errors signal more significant problems that necessitate intervention by qualified personnel. Service Required errors denote critical malfunctions that require professional servicing by a certified technician. When an error code appears‚ consult the error code table in the manual.

Attempt the recommended troubleshooting steps. For User Resettable errors‚ this might involve checking tubing connections‚ power cycling the device‚ or ensuring proper sleeve placement. If the error persists or if a Manual Reset or Service Required error is displayed‚ contact Covidien’s service department or qualified biomedical personnel for assistance. Do not attempt to repair the device yourself‚ as this could void the warranty and potentially cause further damage or harm. Accurate diagnosis and prompt resolution of error codes are essential for maintaining the optimal performance and safety of the Kendall SCD 700 Series.

User Resettable Errors

User Resettable Errors on the Kendall SCD 700 Series are designed to be easily addressed by the user‚ ensuring minimal disruption to therapy. These errors typically indicate minor issues that do not require specialized technical assistance. Common examples of user-resettable errors include those related to tubing connections‚ sleeve application‚ or temporary power fluctuations.

When a user-resettable error occurs‚ the device will display a specific error code along with a brief description of the problem. The user should consult the troubleshooting section of the manual to identify the corresponding error and follow the recommended steps. These steps might involve ensuring that the tubing is securely connected to both the device and the sleeves‚ verifying that the sleeves are properly applied and snug (allowing for two fingers to fit)‚ or power cycling the device.

After addressing the potential cause of the error‚ the user can typically reset the device by pressing a designated button or following the on-screen prompts. If the error persists after attempting these steps‚ it may indicate a more serious issue that requires further attention. In such cases‚ consult the sections on Manual Reset Required Errors or Service Required Errors.

Manual Reset Required Errors

Manual Reset Required Errors on the Kendall SCD 700 Series signal a more significant operational issue compared to user-resettable errors. These errors often indicate internal system malfunctions or persistent problems that necessitate a specific manual intervention to restore normal functionality. Unlike user-resettable errors‚ simply pressing a button will not clear these issues.

When a manual reset is required‚ the device will display an error code and a message indicating that a manual reset is necessary. The user should consult the troubleshooting section of the user manual to identify the error and locate the specific steps for performing a manual reset. The procedure for a manual reset may involve a sequence of button presses or a specific combination of actions outlined in the manual.

It is crucial to follow the instructions precisely‚ as an incorrect procedure may not resolve the error and could potentially exacerbate the problem. If the manual reset is successful‚ the device should return to its normal operating state. However‚ if the error persists even after performing the manual reset correctly‚ it indicates a more severe problem requiring professional service. In such instances‚ refer to the section on Service Required Errors.

Service Required Errors

Service Required Errors on the Kendall SCD 700 Series indicate critical malfunctions that cannot be resolved through user or manual resets. These errors typically point to internal component failures‚ significant system errors‚ or issues that necessitate specialized technical expertise and equipment to diagnose and repair. When the device displays a Service Required Error‚ it is imperative to discontinue use immediately to prevent further damage or potential harm.

Attempting to troubleshoot these errors without proper training and tools can be dangerous and may void any warranties. The user manual provides a list of common service-required error codes‚ but it does not offer troubleshooting steps for these errors. Instead‚ it directs the user to contact Covidien’s service department or a qualified biomedical technician.

Before contacting service personnel‚ record the specific error code displayed on the device‚ as this information will assist the technician in diagnosing the problem more efficiently. Provide a detailed description of the events leading up to the error‚ any unusual observations‚ and the device’s usage history. This information will enable the service technician to arrive prepared and minimize downtime. Service technicians should be familiar with the operator’s section of the manual.

Maintenance and Cleaning Procedures

Proper maintenance and cleaning are crucial for ensuring the longevity and optimal performance of the Kendall SCD 700 Series. Regular cleaning helps prevent the buildup of dust‚ dirt‚ and other contaminants that can impair the device’s functionality. Before cleaning‚ always disconnect the controller from the power source. Use a soft‚ damp cloth to wipe down the exterior surfaces of the controller and tubing. Avoid using harsh chemicals‚ solvents‚ or abrasive cleaners‚ as these can damage the device’s casing and internal components.

Inspect the tubing and connectors regularly for signs of wear‚ cracks‚ or damage. Replace any damaged components immediately to prevent leaks and ensure proper compression therapy. The leg sleeves and foot cuffs should be cleaned according to the manufacturer’s instructions‚ typically involving gentle washing with mild soap and water. Ensure that all components are completely dry before reassembling and using the device.

Do not immerse the controller in water or any other liquid. User maintenance is covered in this section; all other maintenance must be performed by qualified service personnel. Regular maintenance extends the life of the Kendall SCD 700 series.

Battery Information and Charging Instructions

The Kendall SCD 700 Series is equipped with a battery backup that allows for continuous therapy even when disconnected from a power source. The battery provides up to eight hours of operation‚ ensuring uninterrupted treatment during transport or power outages. To maximize battery life and performance‚ follow these charging instructions. Always use the specified charger provided by Covidien to charge the device. Using unauthorized chargers may damage the battery and void the warranty.

To charge the battery‚ connect the charger to the controller and plug it into a standard electrical outlet. The charging indicator light will illuminate‚ indicating that the battery is charging. Allow the battery to charge fully before disconnecting the charger. It is recommended to fully charge the battery before the first use and after extended periods of non-use.

Avoid exposing the battery to extreme temperatures‚ as this can reduce its lifespan and performance. If the battery is not holding a charge or is exhibiting other issues‚ contact Covidien for service and support. Do not attempt to replace the battery yourself‚ as this requires specialized tools and knowledge. The Kendall SCD 700 series will indicate when the battery needs recharged.

Electromagnetic Compatibility Guidelines

The Kendall SCD 700 Series is designed and tested to comply with electromagnetic compatibility (EMC) standards to minimize interference with other electronic devices and to ensure it is not affected by external electromagnetic disturbances. However‚ it’s crucial to adhere to specific guidelines to maintain optimal performance and safety.

The device should be used in an electromagnetic environment as specified in this manual. Medical electrical equipment needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the accompanying documents. Portable and mobile RF communications equipment can affect medical electrical equipment.

To minimize potential interference‚ avoid using the device in close proximity to other electronic equipment that may generate strong electromagnetic fields. Maintain a safe distance from devices such as radio transmitters‚ cellular phones‚ and other high-frequency devices. If interference is suspected‚ try relocating the Kendall SCD 700 Series or the other electronic device. The use of accessories‚ transducers‚ and cables other than those specified‚ may result in increased emissions or decreased immunity of the device. The end user should assure that it is used in such an environment.

Contacting Covidien for Service and Support

For any technical assistance‚ service inquiries‚ or support needs related to your Kendall SCD 700 Series device‚ Covidien offers multiple channels for you to reach out. Whether you require troubleshooting guidance‚ need to schedule a repair‚ or have questions about the device’s functionality‚ their dedicated support team is available to assist you.

You can contact Covidien’s customer service department by calling their toll-free number‚ which is typically available on their website and within the device’s documentation. When calling‚ be prepared to provide the device’s model number and serial number for quicker assistance. Alternatively‚ you can visit the Covidien website to access their online support portal‚ where you can find FAQs‚ troubleshooting guides‚ and other helpful resources.

For more complex issues that require on-site service or repairs‚ Covidien has a network of qualified service technicians who can be dispatched to your location. To arrange for service‚ contact Covidien’s service department‚ and they will guide you through the necessary steps. Ensure that you have the device’s warranty information readily available when requesting service. You can also contact 1-800-962-9888 or visit www.covidien.com for support.